Skip to content
KV2 · Ball valve

KV2-12-18L

2-wayMetricISO 8434-1

A 2-way hydraulic ball valve that opens and closes the flow path. It does not restrict flow, its full-bore design prevents cavitation, and it can be locked open or closed with the locking plate.

KV2-12-18L – Metric
KV2-12-18L · Metric
Dimensions

KV2-12-18L and other products in body size DN12,5

Letters refer to the dimensions on the technical drawing. Click a code to open that product.

Performance

How much can KV2-12-18L take?

Operating conditions and sealing.

500bar
Max. working pressure · series maximum 500 bar
  • Max. working pressure500 bar7252 psi
  • Working temperature−20 / +100 °C
  • Seal materialNBR (standard)FKM, PTFE, EPDM optional
  • Lever movement90°fully open / fully closed
Available on request: Test pressureBurst pressureFlow rate / pressure drop (Kv)Lever turning torque
Request technical data

Where does the oil flow in each lever position?

Konum 1: açık (P → A)
Position 1

Open (P → A)

Oil passes unobstructed.

Konum 2: kapalı
Position 2

Closed

Flow is shut off completely.

Intermediate position

With the lever between the two positions, the valve is half open; do not leave it in this position and do not use it to adjust flow.

Lever direction

With the lever in line with the pipe, the valve is open; at right angles to the line it is closed; the position can be read from outside.

What is this valve made of?

Scroll the table sideways to see all columns
PartMaterial
BodySteel · Zn-Fe (Cr III) plating
Side fittingSteel · Zn-Fe (Cr III) plating
BallSteel · coated
Shaft (lever pin)Steel · coated
LeverCast
Ball seatDelrin (POM)
O-ringNBR (standard)

Maintenance and spare sealing parts

Sealing parts used in this body size.

Scroll the table sideways to see all columns
PartMaterial
O-ring 1.5 × 24 · 2 pcs90 Shore
O-ring 2 × 17 · 2 pcs90 Shore
O-ring 2 × 12 · 1 pc90 Shore
Ball seatDelrin (POM)
Ready-made seal kit codePending

Options for this product

Scroll the table sideways to see all columns
OptionDetails
SealingNBR standard · FKM, EPDM optional
Stainless steel bodyAISI 316L · FKM seal · −20 °C / +200 °C · 250–400 bar
LockingIn the open or closed position with the locking plate
Limit switch / actuatorPending

How is it manufactured and how is it inspected?

  1. 01

    Machining

    The body, side fittings, ball and lever pin are machined on CNC machines at Oleocon.

  2. 02

    Measurement

    The body, side fitting and ball are measured after machining: visual inspection, optical measurement, gauges, dial indicator, height gauge, caliper and fitting gauge are used.

  3. 03

    Plating and incoming inspection

    Plated parts are inspected again before they go to assembly.

  4. 04

    Assembly

    The body is marked; the lever pin, ball, O-rings, PTFE and side fittings are installed; the fitting is tightened and the lever is tested; the handle is fitted.

  5. 05

    Testing

    The assembled valve goes through the test step.

  6. 06

    Packaging

    The valve that passes the test is packed.

What to watch for with this valve

CautionRead before installation and use
  1. Not used for flow adjustment

    The ball valve works at the full positions between the stops. Use FUV / FCV for flow rate adjustment.

  2. Do not leave in an intermediate position

    Always turn the handle fully to the position between the stops.

  3. Do not disassemble under pressure

    Release the line pressure before disassembling the valve.

  4. Do not weld on the side fittings

    Heat damages the O-rings and ball seats.

Other KV2 products with the same body size

Same mounting dimensions, only the connection thread changes · 5 connection options

DN12,5body sizesame body, different connection thread

View all

What does KV2-12-18L mean?

KV2
Series 2-way ball valve
12
Body size DN12,5
18L
Thread M26×1,5 (18L) DIN 2353 metric tube

Instructions and warnings

Before use.

Correct use

For long life and reliable sealing

  1. Keep the flow rate within normal valuesMake sure the flow rate is within normal values.
  2. Protect against abnormal conditionsDo not expose to oscillation, pressure shocks, water hammer, cavitation, or solid and abrasive particles.
  3. Use fully open or fully closedA ball valve works fully open or fully closed; in a half-open position the ball seat wears and sealing is lost. Use FUV / FCV for flow adjustment.
  4. Turn the handle all the way to the stopsAlways turn the lever between the stops to the fully open or fully closed position; the ball seat of a valve left in an intermediate position will be damaged.
  5. Turn slowly under pressureClosing suddenly at high pressure creates a pressure surge in the line; turn the handle slowly and in a single movement.
  6. Operate the valve from time to timeAfter a long period of inactivity, the handle feels stiffer the first time it is turned; open and close the valve at regular intervals.

Warnings

Read before installation and use

  • Do not touch the valves when the operating temperature is below -20 °C or above +50 °C.
  • Make sure the system pressure is below the maximum working pressure.
  • Make sure all connection surfaces are clean so that dirt and dust do not build up in the circuit.
  • Make sure the mounting parts are on the same axis and fully connected.
  • Make sure the Oleocon product you have selected is suitable for your system's temperature, material and pressure requirements.
  • For any other questions, contact the Oleocon technical support team.

Other sizes of this type

Downloads

Request a quote

Fill in the form and our team will get back to you as soon as possible.

Cookie preference

We use measurement cookies to improve the site. They only run with your consent. Cookie Policy

Reject Accept