Skip to content
Multicouplings

V5P

Multicoupling

Multicoupling that connects several hydraulic lines with a single lever movement. Eliminates line mix-up errors and shortens attachment change time; can be connected from both sides under residual pressure.

V5P V5P – Multicoupling
6,3–10Body size
15Product code

Features and benefits

Technical specifications

  • CompatibilityMarket standard
  • Mechanical connectionInternal cams and locking pins
  • Disconnection typeBy turning the lever after the locking system is released
  • Under residual pressureCan be connected from both sides
  • Thread optionsBSPP·NPT·SAE·Metric
  • Valve typeFlat face
  • Working pressureUp to 350 bar (5000 psi)
  • Operating temperature−20 °C/+100 °C

Selection

How is the product code read?

V5P–F–CG–UKUL
Thread UK UL DA DC LS UK = 9/16″-18 UNF, UL = 3/4″-16 UNF, DA = G1/4, DC = G1/2, LS = M14×1,5 (8L)
Line layout A B C G A = 1×6.3, B = 2×6.3, C = 3×6.3, G = 2×10
Connection side F / M F = female half, M = male half
Series Multicoupling series

Technical data

Pressure, flow rate and leakage value of each coupling size.

Scroll the table sideways to see all columns
Coupling sizeWorking pressureBurst pressureFlow rateLeakage per connectionConnect under residual pressure
6.3 (1/4″)PendingPendingPendingPendingPending
10 (3/8″)PendingPendingPendingPendingPending

Technical data

Performance by line layout.

The number and size of couplings on the plate determine the total flow rate the plate can carry and the connection force.

Scroll the table sideways to see all columns
Line layout (code)CouplingsWorking pressureTotal flow rateConnecting lever force
A G1 × 6.3 + 2 × 10PendingPendingPending
B2 × 6.3PendingPendingPending
C3 × 6.3PendingPendingPending
G2 × 10PendingPendingPending
B G2 × 6.3 + 2 × 10PendingPendingPending
C G3 × 6.3 + 2 × 10PendingPendingPending

Technical data

Pressure drop by flow.

Pressure drop across the connection for each body size. Select a size; hover over the chart or enter your flow to read a value.

0.57.3 0.710.2 114.5 1.521.8 229 2.536.3 343.5 3.550.8 458 4.565.3 572.5 51.32 102.64 205.28 307.93 5013.2 10026.4 ΔP (bar) Q (l/min) ΔP (PSI) Q (GPM) ISO 6,3 ISO 10
6,3Estimated From another seriesQCF series coupling data (estimated from the catalogue rated point); extra loss in the plate body is not included.
Rated flow
12l/min
3.2 GPM
Pressure drop at rated flow
1.0bar
15 PSI · catalogue rated point
Source
Estimated From another series
l/min
  • 6,3 1.8 bar26 PSI
  • 10 < 0.50 bar< 7.3 PSI

Read from each size’s curve; sizes outside their curve show “out of range”.

Technical data

How much force can the plate withstand?

Scroll the table sideways to see all columns
ValueDescriptionOleocon
Maximum mechanical strength of the plateThe total separation force of the pressurized lines must not exceed this valuePending
Lever force when connectingForce needed to turn the lever under residual pressurePending
Lever rotation angleThe angle through which the lever turns to the connected positionPending
Calculation:

Separation force (N) ≈ the sum, for each pressurized line, of pressure (bar) × cross-sectional area (cm²) × 10. This value must remain below the strength of the plate.

Installation and use

The plate can be renewed piece by piece.

Scroll the table sideways to see all columns
KitWhat is it for?Oleocon code
Female half / male halfTo take only the machine side or only the attachment sideF / M letter in the code (V5P-F-…, V5P-M-…)
Single coupling (spare)Replacing a single damaged linePending
Seal kitRenewing the seals of a leaking couplingPending
Dust capProtecting couplings from dirt when disconnectedPending
Parking stationKeeping the detached attachment side on the machinePending
Lever and safety lockReplacing a broken or lost leverPending
Guide pins · screws and plugsMounting and closing off unused linesPending
Electrical connection moduleConnecting the electrical signal together with the hydraulicsPending

Instructions and warnings

Before use.

Correct use

For long life and reliable sealing

  1. Before connecting, clean the mating surfaces of all couplings on the plate so that dirt does not enter the system.
  2. Align the two plates on the same axis and make sure the lever is locked all the way.
  3. Do not expose to abnormal operating conditions (for example oscillation, pressure shocks, water hammer, cavitation, solid and abrasive particles).

Warnings

Read before installation and use

  • Do not connect or disconnect while there is flow in the lines (under dynamic pressure).
  • Do not touch the plate when the operating temperature is below -20 °C or above +50 °C.
  • Make sure the system pressure is below the maximum working pressure (350 bar).
  • Protect separated plates from dirt and dust; do not connect with a dirty surface.
  • Make sure the Oleocon product you have selected is suitable for your system's temperature, material and pressure requirements.
  • For any other questions, contact the Oleocon technical support team.

Warnings

Points to watch with a multicoupling.

Caution
  1. Do not force the handle

    Do not turn the lever without releasing the safety lock. Do not use an extension pipe or tool to make the lever easier to turn.

  2. Arrange pressurized and unpressurized lines in order

    Placing pressurized and unpressurized (return) lines alternately on the plate extends seal life.

  3. Check the pressure of each line

    The lowest-pressure coupling on the plate determines the system limit.

  4. Fit the dust cap when disconnected

    A contaminated coupling damages the seal when connected.

Applications

Where is V5P used?

All application areas 8

Downloads

Catalogs, Technical Data and CAD.

You may also like

Related series

Can't find the size or connection you need in the list?

Send us the code or a technical drawing; we will get back to you with a suitable product and price.

Request a quote

Fill in the form and our team will get back to you as soon as possible.

Cookie preference

We use measurement cookies to improve the site. They only run with your consent. Cookie Policy

Reject Accept