Poppet type
6,3–50315bar
ISO 7241-A / B
FCV
Bidirectional (no check) flow control valve
Flow control valve that adjusts flow rate in both directions. For precise control of cylinder and motor speed.
Features and benefits
Technical specifications
- Operating temperature−20 °C/+100 °C
- Working pressureUp to 350 bar
- Dimensions1/4" – 1/2"
- MaterialCarbon steel
- Thread optionsBSP/NPT/SAE
- SealNBR
Technical data
How much flow passes at each number of knob turns?
Users can see in advance which speed they get at how many turns.
| Knob turns (from fully closed) | 6.3 · 1/4″ | 10 · 3/8″ | 12.5 · 1/2″ |
|---|---|---|---|
| 1 turn | Pending | Pending | Pending |
| 2 turns | Pending | Pending | Pending |
| 3 turns | Pending | Pending | Pending |
| 4 turns | Pending | Pending | Pending |
| Fully open | 20 l/min | 30 l/min | 50 l/min |
| Number of turns from fully closed to fully open | Pending | Pending | Pending |
Technical data
Flow–pressure drop curve with the restrictor open and closed.
| Length | Maximum flow rate | Maximum pressure | Pressure drop with restrictor fully open | Leakage with restrictor fully closed |
|---|---|---|---|---|
| 6.3 · 1/4″ | 20 l/min | Pending | Pending | Pending |
| 10 · 3/8″ | 30 l/min | Pending | Pending | Pending |
| 12.5 · 1/2″ | 50 l/min | Pending | Pending | Pending |
Technical data
Does it throttle equally in both directions?
Because the FCV has no check valve, it restricts flow in both directions.
| Length | Maximum flow rate | Loss A → B when fully open | Loss B → A, fully open | Fully closed |
|---|---|---|---|---|
| 6.3 · 1/4″ | 20 l/min | Pending | Pending | Pending |
| 10 · 3/8″ | 30 l/min | Pending | Pending | Pending |
| 12.5 · 1/2″ | 50 l/min | Pending | Pending | Pending |
Installation and use
Flow depends on pressure and oil viscosity.
The FCV is not pressure compensated: at the same setting, speed changes when the load or oil temperature changes.
| Condition | Oleocon FCV |
|---|---|
| Pressure compensation | Not available in this size |
| Viscosity | Pending |
| Cleanliness class | Pending |
| Oil temperature (NBR) | −20 … +100 °C |
| Leakage when closed | Pending |
Installation and use
Is the setting visible from outside?
A tamper-proof knob option is also available.
| Feature | What is it for? | Oleocon FCV |
|---|---|---|
| Locking screw | Locks the setting; does not drift with vibration | ✔ Yes |
| Setting indicator (color band / line) | The setting can be read from outside in turns; the same setting can be passed on exactly to another machine | Pending |
| Tamper-proof knob | The operator cannot change the setting; only service can | Pending |
| Panel mounting | Mounts on the valve control panel; the knob stays outside | Pending |
Installation and use
Why does the speed change after adjustment?
FCV is not pressure-compensated: the setting behaves like a fixed orifice. When load or oil temperature changes, the flow rate passing through, and therefore cylinder speed, changes too.
| Condition | Oleocon FCV |
|---|---|
| Maximum pressure | 350 bar |
| Maximum flow rate | 50 l/min |
| Temperature | −20 … +100 °C |
| Body | Carbon steel |
| Port options | BSP · NPT · SAE |
| Pressure compensation | Not available in this size |
Instructions and warnings
Before use.
Correct use
For long life and reliable sealing
- Do not expose to abnormal operating conditions (for example oscillation, pressure shocks, water hammer, cavitation, solid and abrasive particles).
Warnings
Read before installation and use
- !Do not touch the valve when the operating temperature is below -20 °C or above +50 °C.
- !Make sure the system pressure is below the maximum working pressure.
- !Make sure all connection surfaces are clean so that dirt and dust do not build up in the circuit.
- !Make sure the mounting parts are on the same axis and fully connected.
- !Make sure the Oleocon product you have selected is suitable for your system's temperature, material and pressure requirements.
- !For any other questions, contact the Oleocon technical support team.
Installation and use
Which way do I turn it to increase speed?
-
01
Direction does not matter
FCV has no check valve; it restricts equally in both directions. Port direction does not change the speed.
-
02
Adjustment direction
Turning the adjustment knob in one direction increases the flow rate; turning it the other way decreases it.
-
03
Tighten the locking screw
So the setting does not drift under vibration.
-
04
In a circuit with a lock valve
The flow control valve is fitted between the cylinder and the TLV lock valve.
Applications
Where is FCV used?
Downloads
Catalogs, Technical Data and CAD.
You may also like
Related series
Can't find the size or connection you need in the list?
Send us the code or a technical drawing; we will get back to you with a suitable product and price.