Skip to content
Multicouplings

V5EP

Multicoupling

A multicoupling that connects the hydraulic lines and the electrical connection on a 5-position plate with a single lever movement. Can be custom-designed to customer requirements; flat-face couplings minimize the entry of foreign matter into the system.

V5EP V5EP – Multicoupling
10Body size
13Product code

Features and benefits

Technical specifications

  • CompatibilityMarket standard
  • Mechanical connectionInternal locking pins
  • Disconnection typeBy turning the lever after the locking system is disabled
  • Under residual pressureOn the male side only
  • Thread optionsBSPP·Metric
  • Valve typeFlat face
  • Working pressureUp to 250 bar (3625 psi)
  • Operating temperature−20 °C/+100 °C

Selection

How is the product code read?

V5EP–4–LY–F
Plate side F / M F = fixed (female) plate, M = moving (male) plate
Thread LY DC DBC DB Thread: LY = M22×1,5 (15L) DC = G1/2 DBC = G3/8 + G1/2 DB = G3/8
Line layout 4 5 4/1 Line layout: 4 = 4 × 10 couplings 5 = 4 × 10 couplings + 1 × 12.5 coupling 4/1 = 4 × 10 couplings + 1 × electrical connector (3-pin)
Series Multicoupling series (5-position)

Technical data

Pressure drop by flow.

Pressure drop across the coupling for each body size. Select a body size; hover over the chart to read a value or enter your flow rate.

0.57.3 0.710.2 114.5 1.521.8 229 2.536.3 343.5 3.550.8 458 4.565.3 572.5 102.64 205.28 307.93 5013.2 10026.4 ΔP (bar) Q (l/min) ΔP (PSI) Q (GPM) ISO 10
10From another seriesQCF series coupling data (measured); extra loss in the plate body is not included.
Source
From another series
l/min
  • 10 2.1 bar31 PSI

Read from each size’s curve; sizes outside their curve show “out of range”.

Instructions and warnings

Before use.

Correct use

For long life and reliable sealing

  1. Fix the female (stationary) plate to the body through the mounting holes.
  2. The male plate is the moving part.
  3. Before making hose or pipe connections to the quick couplings, make sure there is no pressure in the lines (cut off the energy in the system).
  4. Lift the plastic dust cap on the female (stationary) plate upward.
  5. Make sure the connection surfaces are clean.
  6. Place the male (moving) plate so that the centering pins line up with the holes in the female part.
  7. Secure the female (stationary) plate by turning the locking lever clockwise.
  8. Make sure the locking lever is seated in its slot.
  9. During disconnection, safely release all pressure inside the system.
  10. Open the locking mechanism and turn the locking lever counterclockwise.
  11. Remove the male (moving) plate by pulling it out slowly.
  12. Fit the dust caps on the female (stationary) and male (moving) plates to protect them from contamination.

Warnings

Read before installation and use

  • In applications where a Multicoupling is used, because of the high pressure, using the device properly prevents harm to machines and people.
  • It is recommended to clean the surfaces of the fixed and moving parts and the centering pins of the Multicoupling before each connection. If this cleaning is not done, dirt, dust and foreign matter will damage the seals inside the Multicoupling. This can cause leakage.
  • During connection, make sure the residual pressure remains on the moving side of the Multicoupling. Release the pressure on the fixed side.
  • Never try to connect or disconnect under dynamic pressure, “while the sample pump is running”.
  • Make sure the system pressure is below the permitted working pressure.
  • Take care to use flexible hoses to connect the multicoupling parts. Avoid installations on the multicoupling that could transmit excessive side load and vibration.
  • Do not disconnect or connect when the oil temperature in the system reaches 80° (176F).
  • Make sure the oil in the system is clean before connecting hydraulic quick couplings to the system.
  • Make sure that all filters and cooling systems are working correctly.
  • Oleocon products used in systems that do not meet these conditions are outside the scope of the warranty.

Applications

Where is V5EP used?

All application areas 2

Downloads

Catalogs, Technical Data and CAD.

You may also like

Related series

Can't find the size or connection you need in the list?

Send us the code or a technical drawing; we will get back to you with a suitable product and price.

Request a quote

Fill in the form and our team will get back to you as soon as possible.

Cookie preference

We use measurement cookies to improve the site. They only run with your consent. Cookie Policy

Reject Accept