PS-401
Pressure relief valve
Pressure relief valve that opens when the system is overloaded, sending excess flow back to the tank and limiting circuit pressure.
Features and benefits
Technical specifications
- Operating temperature−20 °C/+100 °C
- Working pressureUp to 350 bar
- DimensionsFrom 1/2"
- Flow rateUp to 50 l/min
- Thread optionsBSP
- SealNBR
- MaterialAluminium
Selection
How is the product code read?
There is a single model; the code contains no options.
How it works
How does the valve work?
Normally closed. When system pressure reaches the set value, the valve opens and sends the excess flow to the tank, keeping pressure constant.
Normal operation
Oil goes to the circuit; the tank line is closed.
Overpressure
The valve opens and excess oil returns to the tank.
When is it needed?
In every circuit with a pump; it protects the pump and hoses when the cylinder reaches the end of its stroke or the load jams.
Setting
The opening pressure is set with the adjusting screw and locked with the lock nut.
Selection
How it differs from other auxiliary valves.
| Valve | What does it do? | When? |
|---|---|---|
| FUV | Adjusts flow in one direction, free in the reverse | Cylinder speed in one direction only (e.g. lowering) |
| FCV | Adjusts flow rate in both directions | Cylinder / motor speed in both directions |
| CV | Allows flow in one direction only | Preventing backflow |
| TLV | Locks the cylinder in both directions | Holding a load in position for a long time |
| HPV | Shuts off flow if the hose bursts | Safety on load-lifting cylinders |
| PS-401 | Discharges excess pressure to the tank | Protecting the system from overload |
Instructions and warnings
Before use.
Correct use
For long life and reliable sealing
- Do not expose to abnormal operating conditions (for example oscillation, pressure shocks, water hammer, cavitation, solid and abrasive particles).
Warnings
Read before installation and use
- !Do not touch the valve when the operating temperature is below -20 °C or above +50 °C.
- !Make sure the system pressure is below the maximum working pressure.
- !Make sure all connection surfaces are clean so that dirt and dust do not build up in the circuit.
- !Make sure the mounting parts are on the same axis and fully connected.
- !Make sure the Oleocon product you have selected is suitable for your system's temperature, material and pressure requirements.
- !For any other questions, contact the Oleocon technical support team.
Installation and use
Filtration, viscosity, temperature.
| Condition | Oleocon PS-401 |
|---|---|
| Filtration | Pending |
| Viscosity | Pending |
| Oil temperature | −20 … +100 °C |
| Body | Aluminium |
| Sealing | NBR |
Installation and use
A wrongly fitted valve is useless.
Install as close to the pump as possible
The relief valve must be between the pump outlet and the control valve; there must be no valve that can be shut off in between.
Do not restrict the tank line
The tank port must go directly to the tank. Back pressure in the tank line is added to the opening pressure.
Make the setting with a pressure gauge
While turning the adjusting screw, the pressure is read on the pressure gauge; when the setting is done, the lock nut is tightened.
Do not run continuously open
If the valve continuously discharges oil, the oil heats up quickly. The valve should stay closed in normal operation.
Installation and use
Port names and correct placement.
-
01
Pressure line (P)
The line coming from the pump outlet; the valve limits the pressure in this line.
-
02
Tank line (T)
The line through which the opened valve sends oil to the tank; it goes directly to the tank.
-
03
Pressure gauge port
To read the pressure during adjustment.
-
04
Setting and locking
Set the adjusting screw to the desired pressure and tighten the lock nut.
FAQ
The questions users ask most.
Where on the pump is the relief valve fitted?
Between the pump outlet and the control valve; the tank port is connected directly to the tank.
How do I change the setting pressure?
By loosening the lock nut and turning the adjusting screw; check the value with a pressure gauge.
What if there is another relief valve in the circuit?
If the control valve has an internal relief, the PS-401 can be set to a higher value as backup protection.
Can't find your question?Our technical team answers every question about the series.Contact technical support
Applications
Where is PS-401 used?
Downloads
Catalogs, Technical Data and CAD.
You may also like
Related series
Can't find the size or connection you need in the list?
Send us the code or a technical drawing; we will get back to you with a suitable product and price.