Poppet type
6,3–50315bar
ISO 7241-A / B
FUV
One-way (check) flow control valve
Flow control valve that adjusts the flow rate in one direction and allows free flow in the opposite direction. The knob with a locking screw prevents the setting from drifting due to vibration.
Features and benefits
Technical specifications
- Operating temperature−20 °C/+100 °C
- Working pressureUp to 350 bar
- Dimensions1/4" – 1/2"
- MaterialCarbon steel
- Thread optionsBSP/NPT/SAE
- SealNBR
Technical data
How much flow passes at each number of knob turns?
Users can see in advance which speed they get at how many turns.
| Knob turns (from fully closed) | 6.3 · 1/4″ | 10 · 3/8″ | 12.5 · 1/2″ |
|---|---|---|---|
| 1 turn | Pending | Pending | Pending |
| 2 turns | Pending | Pending | Pending |
| 3 turns | Pending | Pending | Pending |
| 4 turns | Pending | Pending | Pending |
| Fully open | 20 l/min | 30 l/min | 50 l/min |
| Number of turns from fully closed to fully open | Pending | Pending | Pending |
Technical data
Flow–pressure drop curve with the restrictor open and closed.
| Length | Maximum flow rate | Maximum pressure | Check valve opening pressure | Pressure drop in free-flow direction (at rated flow rate) | Pressure drop with restrictor fully open |
|---|---|---|---|---|---|
| 6.3 · 1/4″ | 20 l/min | Pending | Pending | Pending | Pending |
| 10 · 3/8″ | 30 l/min | Pending | Pending | Pending | Pending |
| 12.5 · 1/2″ | 50 l/min | Pending | Pending | Pending | Pending |
Technical data
Does it throttle equally in both directions?
No. FUV has a check valve: it restricts only in the controlled direction; in the opposite direction the oil passes freely through the check valve.
| Direction | What happens? | Pressure drop fully open | Fully closed |
|---|---|---|---|
| Controlled direction (cylinder to valve) | Throttled with the knob to set the speed | Pending | Pending |
| Free direction (valve to cylinder) | Check valve opens, no throttling | Pending | Free flow |
Installation and use
Flow depends on pressure and oil viscosity.
FUV is not pressure-compensated: at the same setting, speed also changes when load or oil temperature changes.
| Condition | Oleocon |
|---|---|
| Pressure compensation | Not available in this size |
| Viscosity | Pending |
| Cleanliness class | Pending |
| Oil temperature (NBR) | −20 … +100 °C |
| Leakage when closed | Pending |
Installation and use
Is the setting visible from outside?
| Feature | What is it for? | Oleocon FUV |
|---|---|---|
| Locking screw | Locks the setting; does not drift with vibration | ✔ Yes |
| Setting indicator (color band / line) | The setting can be read from outside in turns; the same setting can be passed on exactly to another machine | Pending |
| Tamper-proof knob | The operator cannot change the setting; only service can | Pending |
| Panel mounting | Mounts on the valve control panel; the knob stays outside | Pending |
Installation and use
Why does the speed change after adjustment?
FUV is not pressure-compensated: the setting behaves like a fixed orifice. When load or oil temperature changes, the flow rate passing through, and therefore cylinder speed, changes too.
| Condition | Oleocon FUV |
|---|---|
| Maximum pressure | 350 bar |
| Maximum flow rate | 50 l/min |
| Temperature | −20 … +100 °C |
| Body | Carbon steel |
| Port options | BSP · NPT · SAE |
| Pressure compensation | Not available in this size |
Instructions and warnings
Before use.
Correct use
For long life and reliable sealing
- Do not expose to abnormal operating conditions (for example oscillation, pressure shocks, water hammer, cavitation, solid and abrasive particles).
Warnings
Read before installation and use
- !Do not touch the valve when the operating temperature is below -20 °C or above +50 °C.
- !Make sure the system pressure is below the maximum working pressure.
- !Make sure all connection surfaces are clean so that dirt and dust do not build up in the circuit.
- !Make sure the mounting parts are on the same axis and fully connected.
- !Make sure the Oleocon product you have selected is suitable for your system's temperature, material and pressure requirements.
- !For any other questions, contact the Oleocon technical support team.
Installation and use
Which way do I turn it to increase speed?
-
01
Connect it in the right direction
The controlled direction is from the cylinder to the valve; in the opposite direction the oil passes freely through the check valve.
-
02
Adjustment direction
Turning the adjusting screw one way increases the flow rate; turning it the other way decreases it.
-
03
Tighten the lock nut
So the setting does not drift under vibration.
-
04
In a circuit with a lock valve
The flow control valve is fitted between the cylinder and the TLV lock valve.
Applications
Where is FUV used?
Downloads
Catalogs, Technical Data and CAD.
You may also like
Related series
Can't find the size or connection you need in the list?
Send us the code or a technical drawing; we will get back to you with a suitable product and price.